12inch Medical Patient Monitor Vital Sign 6-parameter NIBP SPO2 ECG TEMP RESP PR

$ 242.35

Availability: 10 in stock
  • Return shipping will be paid by: Seller
  • Item must be returned within: 30 Days
  • Screen Dimensions: 12" TFT display
  • Condition: New
  • Multi-language: English, Spanish, Turkish.
  • Features: portable, convenient for use
  • Suitable for: adult, pediatrics and neonate patients
  • Restocking Fee: No
  • CE FDA: passed
  • Refund will be given as: Money back or replacement (buyer's choice)
  • MPN: Does Not Apply
  • Features1: Audible & visual alarm available, adjustable
  • Optional:: Printer ETCO2 (side stream)
  • UPC: 190891820013
  • Brand: Unbranded
  • Warranty: 2 years
  • All returns accepted: Returns Accepted

    Description

    Tips:
    12.1-inch Display 6-Parameter Patient Monitor ----ECG, NIBP, SPO2, TEMP, RESP, PR
    Model: RPM-9000A
    Features
    Ergonomic design, portable, convenient for use
    12" TFT display, configurable up to 8 waveforms, enables maximum data visibility for the most critical parameters
    Unique digital SPO2 technology can work accurate during motion and low perfusion
    Anti AC & high-frequency electrosurgical & defibrillator’s interference
    Rich screen layout, standard, large font, trend graph, OxyCRG, ECG full lead and others
    Strong data storage: 720 hours trends, 10000 group NIBP, 1024 alarms events
    ST analysis, arrhythmia analysis, pacemaker analysis, drug analysis and calculation
    Audible & visual alarm available, adjustable
    Patient information management function
    Powerful software function to support use in NICU, ICU, OR, CCU or normal patient room
    Optional software upgrading based on USB
    Wired/wireless networking with central monitoring system, up to 64 beds in one group
    Built-in 3 trace thermal recorder for printing real-time and historical data
    Multi-language i.e. English, Spanish, Turkish.
    Super long life rechargeable Lithium battery upto 4 hours of working time
    Suitable for adult, pediatrics and neonate patients
    Standard configuration
    ECG, NIBP, SPO2, TEMP, RESP, PR, Rechargeable Lithium battery
    Optional
    Dual TEMP
    Dual IBP
    ETCO2 (side stream)
    Thermal recorder
    Wall mount
    Trolley
    Specification
    ECG
    Full lead: I, II, III, AVL, AVR, AVF and V
    Gain: 5mm/mV, 10mm/mV, 15mm/mV, 20mm/mV and 25mm/mV
    Scanning speed: Changeable with three grades of 12.5mm/s, 25mm/s and 50mm/s
    Band width: 0.05Hz-100Hz(3dB)
    Heart rate
    Scope: 15 times/minute to 300 times/minutes
    Accuracy:  ±1 time/minute
    Variation of heart beat LORENZE drawing: Analysis on heart beat data for the current 5 minutes with histogram during RR period.
    Arrhythmia: Twenty kinds of common abnormal ECG can be analyzed, with ECG data of 1000 times of arrhythmia kept and with 10 seconds kept for each time.
    Accuracy: Error rate < 20%
    Undetected rate < 20%
    ST section
    Scope:     ±0.8mV
    Precision :  < ±0.05mV
    SpO2
    Detection scope:   0%-100%
    Accuracy         ±1%     90%-100%
    ±2%      70%-89%
    NIBP
    Theory Electric oscillator
    Cuff gassing time   less than 15 seconds
    First-time gassing : dynamic state 24kPa(180 mmHg)
    Manual selection: 9.3kPa(70 mmHg),13.3kPa(100 mmHg),16.0kPa(120 mmHg)
    18.6kPa(140 mmHg),20.0kPa(150 mmHg),21.3kPa(160 mmHg),
    Automatic detection period: 1 minute to 240 minutes
    Stop size:1 min(1 min -10min), 5min(10 min -30min), 10min(30 m
    in -90min) and 30min(90 min -240min)
    Detection scope:
    Systolic blood presure:   4kPa -34kPa(30mmHg -255mmHg)
    Diastolic presure             2kPa -29.3kPa(15mmHg -220mmHg)
    Mean presure               2.7kPa~31.3kPa       (20mmHg~235mmHg)
    Detection accuracy
    Static presure: ±3mmHg
    Pulse rate:  ±2%
    Resp
    Chest impedance method or concentration of carbon dioxide at end of respiration
    Scope of chest impedance method     0 time/minute – 100 minutes/minute
    Precision of chest impedance method  time/minute
    Detection scope of carbon oxygen at end of respiration 3mmHg-75mmHg; 0.4%vol-9.9%vol
    Detection scope of respiration rate: 2 times/minute ->60 times/minute(including baby)
    Detection precision of respiration rate: ±1 time/minute
    Temp
    Single/double path
    Type:    Vascular/surface temperature
    Scope:    20℃~50℃
    Accuracy:  ±0.2℃
    Shippment
    1.All items will be shipped to buyer's PayPal address.Please make sure your PayPal address is correct.
    About Warranty
    We guarantees new equipment other than accessories to be free from defects in workmanship and materials for a period of twelve months (six months for spare parts) from the date of shipment under normal use and service. Our company's obligation under this warranty is limited to repairing, at our company's option, any part which upon our company's examination proves defective.
    The FDA Statement
    The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. If so, do not bid on this item unless you are an authorized purchaser. If the item is subject to FDA regulation, we will verify your status as an authorized purchaser of this item before shipping of the item.
    Return Policy
    If you have a defective item which you want to return, please contact us within 2 days from you receive the item. All return items must be returned with its original packaging and accessories. Customer is responsible for shipping charges on returned items.
    We will refund the money to you when we get the return items. Or replace item for you.